Frost on the large copper line
Usually visible at the outdoor unit or at the air handler.
Air conditioning
Ice on the copper lines or on the indoor coil means your air conditioner is starved for heat to absorb. We thaw it safely, find out whether airflow or refrigerant is the cause, and fix the real problem.

A frozen AC is usually caused by low airflow from a dirty filter, a blocked coil or a failing blower, or by low refrigerant from a leak. In Virginia Beach, diagnosis and the typical fix run $165 to $725. Switch the thermostat to fan only to start thawing, and do not chip at the ice.
An evaporator coil normally runs around 40 degrees. If too little warm air crosses it, or if refrigerant pressure drops from a leak, the coil temperature falls below 32 and the moisture it is removing turns to ice. The ice blocks more airflow and the problem feeds on itself until the whole coil and suction line are white.
Thawing takes a few hours with the fan running. Once it is clear, we test airflow, check the blower speed and motor, inspect the coil face, and measure refrigerant pressures. Each cause has a different fix, so we do not guess.
How the visit goes
Fan only or off, with towels near the unit for meltwater.
Filter, return grilles, blower wheel and motor.
Face of the coil inspected for dirt or matting.
Pressures and superheat, with a leak search if low.
The cause is repaired and the coil watched through a full cycle.
What to watch for
Usually visible at the outdoor unit or at the air handler.
Ice on the coil chokes airflow.
Melting ice can overflow the pan.
An iced coil cannot absorb heat.
A packed filter is the simplest and most common cause.
Furniture over a return grille can starve the system.
Typical price range
$165 to $725
Diagnosis and typical fix. A typical range for Virginia Beach homes, not a quote. You get an exact price before any work starts.Compare ranges for every service on our typical prices page.
Local know-how
We see a wave of frozen systems in late May and June, when people run the AC hard for the first time with a filter that has been in since fall. Pollen season fills filters fast here.
Some homes run the thermostat very low on humid nights to feel dry. A system set to 65 on a mild night can freeze even with a clean filter, especially if it is oversized.

Coverage
We cover all of Virginia Beach and the surrounding cities and counties. These are some of the areas we visit most often for this work.
Related work
If your system needed refrigerant last year and needs it again, it has a leak.
See Refrigerant leak repairThe air handler moves every bit of air in a heat pump system.
See Air handler repairWhen the air conditioner runs warm, short cycles or quits on a muggy Virginia Beach afternoon, we find the actual failed part, show you the reading that proves it and fix it on.
See AC repairThe filter slot on many systems is too small to filter well without choking airflow.
See Air filtration
The thermostat says 74 but the house feels sticky. Here is why that happens in Virginia Beach homes and what actually fixes it.
Questions
Switch to fan only if the blower works, which thaws faster. If water is overflowing, turn it off.
Usually two to four hours. A thick block can take longer.
Yes. Liquid refrigerant can return to the compressor. Do not keep running it in cooling mode.
If the filter was the cause, often yes. If it freezes again with a clean filter, call us.
Call (757) 529-6260. A person answers 24 hours a day, and you get the price before any work starts.